Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add filters








Year range
1.
Chinese Journal of Orthopaedics ; (12): 746-752, 2022.
Article in Chinese | WPRIM | ID: wpr-957064

ABSTRACT

Objective:To investigate the clinical effect of peroneal fracture line in the treatment of posterior Pilon fracture.Methods:The data of 26 patients treated with fibular fracture line from January 2017 to July 2019 were analyzed retrospectively, including 11 males and 15 females; the age ranged from 28 to 69 years, with an average of 42.2 years. There were 10 cases of falling injury, 9 cases of falling injury and 7 cases of traffic injury; all of them were fresh closed fibular fractures;According to Yu Guangrong's classification, there were 11 cases of type I, 8 cases of type II and 7 cases of type III; AGH was divided into 10 cases of type I, 5 cases of type IIa, 2 cases of type IIb, 5 cases of type IIIa and 4 cases of type IIIb. All cases were treated by opening the fibular fracture line through the posterolateral approach, the quality of fracture reduction was evaluated by Burwell Charnley radiological evaluation standard after operation; At the last follow-up, ankle function was evaluated by American Association of Foot and Ankle surgery (AOFAS) ankle and hindfoot scores.Results:All 26 patients were followed up for 12-23 months, with an average of 14.9 months; Bone healing was achieved in all fractures. The healing time was 3-6 months, with an average of 4.0 months. The quality of fracture reduction was evaluated according to the Burwell Charnley radiology evaluation standard after operation, including anatomical reduction in 23 cases and acceptable reduction in 3 cases. The anatomical reduction rate was 88% (23/26). At the last follow-up, AOFAS ankle and hindfoot scores ranged from 80 to 100, with an average of 89.9 points, of which 17 cases were excellent and 9 cases were good, and the excellent and good rate was 100%. At the last follow-up, no patient had complications such as reduction loss, skin necrosis, infection, internal fixation loosening or ankle stiffness.Conclusion:After the treatment of Pilon fractures via peroneal fracture line, the distal tibial articular surface and posterior ankle fracture gap can be fully exposed, which can be repositioned and fixed under direct vision, with high anatomical repositioning rate and good and safe clinical results.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 943-949, 2022.
Article in Chinese | WPRIM | ID: wpr-956611

ABSTRACT

Objective:To compare closed reduction and intramedullary nailing versus open reduction and locking plate fixation in the treatment of middle and upper humeral fractures.Methods:A retrospective case-control study was conducted to analyze the clinical data of 62 patients with middle and upper humeral fracture who had been treated at Department of Orthopaedics, The First People's Hospital of Jinmen and at Department of Orthopedics, General Hospital of PLA Central Theater from October 2017 to February 2021. There were 35 males and 27 females, aged from 27 to 86 years. The left side was affected in 24 cases and the right side in 38 cases. All fractures were fresh. According to the AO classification, 16 cases were type A, 32 type B, and 14 type C. Of the patients, 29 were treated with closed reduction and intramedullary nailing (intramedullary nail group) and 33 with open reduction and locking plate fixation (locking plate group). The length of incision, operation time, intraoperative blood loss, hospital stay, fracture healing and complications were recorded and compared between the 2 groups. The pain degree was evaluated by visual analogue scale (VAS) at one week and one month after operation, and the functional recovery of the shoulder was evaluated by Constant-Murley score at one month and 12 months after operation.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The intramedullary nail group was followed up for 12 to 29 months and the locking plate group for 15 to 50 months. In the intramedullary nail group, the length of incision [(4.1±0.7) cm], operation time [(58.3±7.7) min], intraoperative blood loss [(52.7±6.5) mL], and hospital stay [(7.3±1.5) d] were significantly less than those in the locking plate group [(21.7±2.3) cm, (95.8±11.7) min, (237.4±14.9) ml, and (12.3±1.7) d] ( P<0.05). The fracture healing time in the intramedullary nail group was (5.0±1.9) months, significantly longer than that in the locking plate group [(3.5±1.7) months] ( P<0.05). The VAS scores at one week and one month after operation in the intramedullary nail group [(2.8±0.3) points and (1.2±0.5) points] were significantly lower than those in the locking plate group [(4.3±0.4) points and (1.6±0.5) points], and the Constant-Murley score at one month after operation in the intramedullary nail group [(63.5±7.4) points] was significantly higher than that in the locking plate group [(54.3±6.9) points] ( P<0.05). However, at 12 months after operation, there was no significant difference in the Constant-Murley score between the 2 groups ( P>0.05). In both groups, the VAS score at one month after operation was significantly lower than that at one week after operation while the Constant-Murley score at 12 months after operation was significantly higher than that at one week after operation ( P<0.05). In the intramedullary nail group, intraoperative distal refracture happened in one case; in the locking plate group, incision infection occurred in one case and postoperative radial nerve injury in another. There was no significant difference in the incidence of complications between the 2 groups [3.4% (1/29) versus 6.1% (2/33)] ( P>0.05). Conclusion:In the treatment of middle and upper humeral fractures, compared with open reduction and locking plate fixation, closed reduction and intramedullary nailing shows advantages of a smaller surgical incision, shorter operation time, less intraoperative blood loss, shorter hospital stay and faster functional recovery.

3.
Chinese Journal of Trauma ; (12): 1105-1111, 2021.
Article in Chinese | WPRIM | ID: wpr-909983

ABSTRACT

Objective:To compare the effect of interlocking intramedullary nail and locking plate in the treatment of varus proximal humeral fractures in the elderly.Method:A retrospective case-control study was conducted to analyze the clinical data of 46 elderly patients with varus proximal humeral fractures treated in Central Theater General Hospital of PLA from June 2016 to January 2019, including 27 males and 19 females, at age of 60-84 years[(71.9±5.7)years]. All fractures were fresh. Overall 25 patients were treated with interlocking intramedullary nail(intramedullary nail group), and 21 patients were treated with locking plate(bone plate group). The incision length, operation time, intraoperative bleeding and fracture healing time were compared between the two groups. Visual analogue scale(VAS)was used to evaluate the degree of pain relief at 1 week and 1 month after operation, and Constant-Murley score was used to evaluate the recovery of shoulder function at 1 month, 3 months and 1 year after operation. The cervical trunk angle was recorded at 2 days and 1 year after operation to judge whether there was a loss of cervical trunk angle. Postoperative complications were observed.Results:All patients were followed up for 12-32 months[(19.7±6.6)months]. The incision length[(7.1±0.6)cm], operation time[(60.8±5.2)minutes], intraoperative bleeding[(64.4±8.4)ml]and fracture healing time[(10.0±1.0)weeks]in intramedullary nail group were significantly less than those in bone plate group[(13.6±0.9)cm,(80.2±8.1)minutes,(151.0±15.2)ml,(11.0±1.5)weeks]( P<0.05). In both groups, the VAS decreased significantly over time, and markedly increased Constant-Murley score was detected as well( P<0.05). The VAS in intramedullary nail group[(2.8±0.2)points,(1.1±0.2)points]was significantly lower than that in bone plate group[(4.0±0.2)points,(1.5±0.1)points]at 1 week and 1 month after operation( P<0.05). The Constant-Murley score in intramedullary nail group[(59.9±6.9)points,(79.1±6.8)points]was higher than that in bone plate group[(50.1±8.5)points,(73.6±8.4)points]at 1 month and 3 months after operation( P<0.05), but the score showed no significant difference between intramedullary nail group[(89.1±5.3)points]and bone plate group[(86.4±6.4)points]at 1 year after operation( P>0.05). According to Constant-Murley score, 10 patients were evaluated as excellent and 15 patients as good in intramedullary nail group at 1 year after operation, with the excellent and good rate of 100%, while 8 patients were evaluated as excellent, 11 patients as good and 2 patients as fair in bone plate group at 1 year after operation, with the excellent and good rate of 91%( P>0.05). The cervical trunk angle in intramedullary nail group[(140.2±2.9)°,(139.6±2.3)°]had significant difference from that in bone plate group[(139.6±3.2)°,(138.8±3.3)°]at 2 days and 1 year after operation( P<0.05). In both groups, the cervical trunk angle had slight lost at 1 year after operation compared with that at 2 days after operation, but the difference was not statistically significant( P>0.05). In intramedullary nail group, 1 patient had subacromial impact. In bone plate group, 1 patient had screw cutting, 2 patients subacromial impact, and 2 patients delayed fracture healing. The incidence of complications in intramedullary nail group was 4%(1/25), lower than 24%(5/21)in bone plate group( P<0.05). Conclusion:Compared with locking nail plate, interlocking intramedullary nail in the treatment of senile varus proximal humeral fracture has the advantages of small trauma, early fracture healing, less pain, early function recovery and less complications.

4.
Chinese Journal of Orthopaedic Trauma ; (12): 955-959, 2020.
Article in Chinese | WPRIM | ID: wpr-867962

ABSTRACT

Objective:To evaluate the efficacy of lateral deltoid muscle approach in the treatment of valgus-impacted three- and four-part fractures of the proximal humerus.Methods:From January 2015 to December 2017, 36 patients were treated at Department of Orthopaedics, General Hospital of Central Military Theater for valgus-impacted three- and four-part fractures of the proximal humerus via the lateral deltoid muscle approach. They were 10 men and 26 women, aged from 38 to 85 years (mean, 65.6 years). The fracture had occurred at the left side in 20 cases and at the right side in 16. According to the Neer classification, 22 cases had a three-part fracture and 14 a four-part one. Their operation time and intraoperative bleeding were recorded. The efficacy was evaluated by their Constant-Murely scores and ranges of motion of the shoulder joint one year after operation.Results:This cohort was followed up for 12 to 36 months (mean, 21.7 months). Their operation time ranged from 55 to 120 min (mean, 75.9 min); their intraoperative bleeding ranged from 50 to 200 mL (mean, 109.7 mL). Their Constant-Murely scores of the affected shoulder one year after operation ranged from 79 to 90 points (mean, 84.1points). At one year after operation, their abduction ranged from 90° to 160° (mean, 120.6°), their uplift from 90° to 170° (mean, 128.1°), their backward extension from 20° to 60° (mean, 38.8°), their internal rotation from 20° to 45° (mean, 30.5°), and their external rotation from 30° to 45° (mean, 35.6°). All patients obtained bony union with no such complications as axillary nerve injury, deep infection, nonunion or ischemic necrosis of the humeral head.Conclusion:Treatment of valgus-impacted three- and four-part fractures of the proximal humerus via the lateral deltoid muscle approach is minimally invasive, simple, safe and effective.

5.
Chinese Journal of Trauma ; (12): 228-232, 2020.
Article in Chinese | WPRIM | ID: wpr-867702

ABSTRACT

Objective:To investigate the clinical effect of treatment of valgus impacted proximal humeral fracture in elderly patients with locking plate internal fixation through deltoid approach.Methods:A retrospective case series study was carried out to analyze the clinical data of 25 elderly patients with valgus impacted proximal humeral fracture hospitalized in Central Theater General Hospital of PLA from September 2016 to March 2018, including 7 males and 18 females, aged 60-81 years [(67.9±9.1)years]. According to Neer classification, 21 patients were with three part proximal humeral fracture and 4 with four part fracture. All patients were treated by internal fixation with locking plate through deltoid approach. Rehabilitation exercise training was done after operation. Total length of incision, operation time, intraoperative bleeding volume and fracture healing were recorded. At the last follow-up, the range of motion and abductor muscle strength of the shoulder joint between the affected side and the healthy side were compared, joint function was evaluated using the Constant-Murley score, and the postoperative complications were observed.Results:All patients were followed up for 12-23 months [(14.6±3.2)months]. Total length of incision was 6.4-8.8 cm [(7.1±1.2)cm]. Operation time was 68-106 minutes[(84. 0±5.6)minutes]. Intraoperative bleeding volume was 55-95 ml [(62.5±16.4)ml]. All the fracture lines were well reduced and bony union was observed in all patients at popstoperative 6 months. At the last follow-up, there was no significant difference in flexion, abduction, pronation range and abductor muscle strength between the affected side and the healthy side ( P<0. 05). At the last follow-up, the Constant-Murley score of shoulder joint function was excellent in 9 patients, good in 13, fair in 3, with excellent and good rate of 88%. There was no subacromial impact, humeral head necrosis or other complications after operation. Conclusion:Locking plate through deltoid approach in treatment of valgus impacted proximal humeral fracture in the elderly has the advantages of less operative trauma, shorter operative time, less intraoperative bleeding, less postoperative complications, good reduction of fracture and good functional recovery of shoulder joint.

6.
Chinese Journal of Tissue Engineering Research ; (53): 2223-2227, 2019.
Article in Chinese | WPRIM | ID: wpr-743882

ABSTRACT

BACKGROUND: Development of bone tissue engineering provides a new method to solve bone defect repair. Scaffold material and structure construction are issues of concern. OBJECTIVE: To fabricate a silk fibroin and hydroxyapatite scaffold with biomimetic interconnected macropores structure using the paraffin-sphere leaching technology and to evaluate its possibility of cytocompatibility. METHODS: The scaffold with biomimetic interconnected macropores structure was made by the paraffin-sphere leaching technology. The structure of scaffold was observed by the stereomicroscope and scanning electron microscope. The pore size and elasticity modulus were calculated. Passage 3 rabbit adipose-derived mesenchymal stem cells were seeded into the scaffold. The cell viability was detected by live/dead staining at 48 hours after culture. The cell adhesion was observed by hematoxylin-eosin staining at 1 week of culture. The scaffold-cell composite was observed under scanning electron microscope at 3 days of culture. The cell proliferation was detected by the cell counting-kit 8 assay at 1, 3, 5 and 7 days of culture. Those cells cultured alone were considered as control group. RESULTS AND CONCLUSION: (1) Stereomicroscope showed the ivory silk fibroin/hydroxyapatite scaffold. Scanning electron microscope revealed pore structures in cross-section and longitudinal-section with good connectivity. The scaffold pore size was (362.23±26.52) μm and the elasticity modulus was (54.93±5.44) kPa. (2) Scanning electron microscope showed that adipose-derived mesenchymal stem cells adhered and stretched well in the pore wall and connected pore, secreted abundant extracellular matrix, and filled in the pores of silk fibroin/hydroxyapatite scaffold. (3) Hematoxylin-eosin staining results found that adipose-derived mesenchymal stem cells evenly adhered onto the inner wall of silk fibroin/hydroxyapatite scaffold, and proliferated well. (4) Live/dead staining revealed a good viability of adipose-derived mesenchymal stem cells. (5) Cell counting-kit 8 assay results showed the good proliferation of adipose-derived mesenchymal stem cells on the scaffold. (6) To conclude, the silk fibroin/hydroxyapatite scaffold possesses good pore size and cytocompatibility.

7.
Chinese Journal of Orthopaedics ; (12): 101-109, 2018.
Article in Chinese | WPRIM | ID: wpr-708514

ABSTRACT

Objective To summarize the characteristics of deltoid ligament rupture and explore the feasibility and shortterm clinical outcomes of targeted suture anchor repair technique according to the rupture site.Methods From May 2011 to October 2014,19 cases of complete deltoid ligament rupture (17 males and 2 females) were recruited in this study,with an average age of 34.15± 1.23 years (ranged from 15 to 60 years).According to Lauge-Hansen classification,there were 7 cases of pronation external rotation grade ⅣV injury,including 3 cases of Maisonnuve fracture;1 case of pronation abduction type Ⅲ degree injury,1 case of pronation abduction grade ⅣV injury;and 10 cases of supination external rotation grade ⅣV injury.According to AO / OTA classification,there were 9 cases of 43B type injury and 10 cases of 43C type injury.According to the rupture site of deltoid ligament,the targeted suture anchor repair surgery was operated respectively.Early mobilization with the help of hinged ankle brace was encouraged.The evaluation at last follow-up was based on the American Orthopedic and Ankle Association (AOFAS) criteria of ankle and hindfoot,and the visual analogue scale (VAS) scoring system.Results Nineteen patients were all followed up for 24 to 48 months,with an average of 30.42±5.11 months.Fourteen cases (73.7%,14/19) with talus end avulsion were treated by double suture anchor in the talus,with continuous locking suture of the avulsed end.Four cases (21.1%,4/19) with middle part rupture were treated by double suture anchor in the talus,with the sutures crossing three bone tunnels at the medial malleolus.One case (5.3%,1/19) with medial malleolus end avulsion was treated by single suture anchor at the medial malleolus,with continuous locking suture of the avulsed end.At the last follow-up,the AOFAS score was ranged from 70 points to 96 points,with an average of 90.53 points,and excellent in 16 cases,good in 2 cases,fair in 1 case,excellent and good rate was 94.7%.The VAS score was ranged from 0 to 2 points,with an average of 0.42 point.No wide medical clear space was detected.But traumatic arthritis was happened in 2 patients.Conclusion The targeted suture anchor repair technique according to the rupture site was a save technique in treating deltoid ligament rupture,which is conducive to early postoperative functional exercise,with excellent short-term clinical outcomes and few complications.

8.
Chinese Journal of Orthopaedic Trauma ; (12): 16-21, 2018.
Article in Chinese | WPRIM | ID: wpr-707422

ABSTRACT

Objective To investigate application of modified isosceles triangle osteotomy which is designed with the assistance of Picture Archiving and Communication System ( PACS ) in supracondylar surgery for cubitus varus. Methods We reviewed the 31 patients who had been treated for cubitus varus from January 2012 to July 2017. They were 12 males and 19 females, aged from 17 to 24 years ( average, 20. 6 years) . Their elbow varus angles ranged from 14° to 35° (average, 22. 4°) . Preoperatively, the modified isosceles triangle osteotomy was designed using the PACS. The angle of osteotomy = carrying angle of the normal arm + the angle of cubitus varus. The lateral length of the isosceles triangle osteotomy was calculated according to the osteotomy angle. All the cases were fixated with a locking plate. Results The follow-ups lasted from 12 to 40 months ( average, 16 months ) . Bony union was achieved in the osteotomy site by all cases after 7 to 12 weeks ( average, 9 weeks ) . The carrying angles ranged from 8° to 15° ( average, 11°) at final follow-ups. The affected elbow obtained a range of flexion and extension from 126° to 150° ( average, 139°) and a range of rotation from 134° to 160° ( 144°) . According to the Mayo elbow performance score ( MEPS ) one year after operation, 23 cases were rated as excellent, 7 as good and one as fair, yielding an excellent to good rate of 96. 8%. No loss of carrying angle, neural deficit, malunion, delayed union, or myositis ossifi-cans of the elbow was observed during the follow-ups. Conclusion The PACS can be used in preoperative design of the modified isosceles triangle osteotomy for cubitus varus, leading to accuracy in the angle and length of the osteotomy to guarantee fine clinical results.

9.
Chinese Journal of Trauma ; (12): 345-350, 2018.
Article in Chinese | WPRIM | ID: wpr-707312

ABSTRACT

Objective To evaluate the clinical effect of mini-plate internal fixation via anterior elbow approach in treating coronoid process fractures.Methods A retrospective case series study was conducted on the clinical data of 43 cases of ulnar coronoid process fractures treated from December 2014 to December 2016.There were 29 males and 14 females,with an average age of 32.4 years (range,24-64 years).Twenty-four cases were injured on the right,and 19 on the left.There were 18 cases of simple coronoid process fractures,23 combined with ipsilateral capitulum radius fractures,and two combined with ipsilateral ulna olecranon fractures.According to the O'Driscoll classification,there were four cases of type Ⅰ,3 type Ⅱa,9 type Ⅱb,17 type Ⅱc,6 type Ⅲa,and 4 type Ⅲb.The elbow flexion and extension range was 40°-90°[(64 ± 18)°],and the rotation range 60°-130°[(83 ± 15)°].All the patients underwent mini-plate internal fixation via anterior elbow approach.The operation time,intraoperative blood loss,wound healing,fracture healing,and postoperative complications were recorded.Function of elbow joint was evaluated by Mayo elbow performance score (MEPS).Results All patients were followed up for 12-24 months (mean,15.7 months).The average operation time was 52 minutes (range,36-86 minutes).The average blood loss was 20 ml (range,10-50 ml).At the last follow-up,all were seen incision healing by first intention and clinical fracture healing.The index finger,and middle finger palmaris numbness occurred in one patient after surgery,and the patient recovered at 2 months of follow up.The elbow flexion and extension range was 86°-145° [(117 ± 114) °],and the rotation range of 114°-155° [(132 ± 17) °],showing significant difference in comparison with the preoperative measure (P < 0.05).According to the MEPS one year after operation,14 cases were evaluated excellent,27 good,and four fair,with an excellent and good rate of 91%.Conclusion The mini-plate internal fixation via the anterior elbow approach is effective in treating ulnar coronoid process fractures,for the operation is simple,allows full exposure,reduction,or reconstruction under direct vision,and effectively restores the function of the elbow joint.

10.
Chinese Journal of Orthopaedic Trauma ; (12): 79-82, 2016.
Article in Chinese | WPRIM | ID: wpr-490612

ABSTRACT

Objective To evaluate the efficacy of anatomical locking titanium plate via the posterior elbow approach in the treatment of comminuted fractures of proximal ulna.Methods From January 2011 to December 2013,22 comminuted fractures of proximal ulna were treated by anatomical locking titanium plate via the posterior elbow approach.They were 14 men and 8 women,from 21 to 57 years of age (average,42.7 years).Nine cases were on the left side and 13 on the right.All were unilateral closed fractures.By the Schatzker classification,12 cases were type Ⅲ A,6 type Ⅲ C and 4 a combination of type Ⅲ A and type Ⅲ C.The Broberg & Morrey criteria were used to evaluate the elbow function one year postoperation.Results The follow-ups for the 22 cases ranged from 12 to 24 months (average,16 months).All the cases obtained clinical healing after 10 to 16 weeks (average,13 weeks).According to the Broberg & Morrey criteria,12 cases were evaluated as excellent,7 as good,and 3 as fair,yielding an excellent to good rate of 86.4%.No such complications as infection or necrosis of soft tissues,elbow stiffness,or obvious pain were observed during the follow-up period.Conclusion It is an effective treatment of comminuted fractures of proximal ulna with anatomical locking titanium plate through the posterior elbow approach.

11.
Chinese Journal of Tissue Engineering Research ; (53): 2577-2581, 2009.
Article in Chinese | WPRIM | ID: wpr-406559

ABSTRACT

BACKGROUND: Chinese anatomical parameters of antedor atlantoaxial transarticular screw fixation have been rarely reported although the technique is a novel method out of China for patients with C1-C2 instability. OBJECTIVE: To provide Chinese anatomical data for anterior C1-C2 transarticular screw fixation. DESIGN, TIME AND SETTING: A measurement experiment was performed at the Department of Anatomy, Southern Medical University and Department of Orthopedics, Wuhan General Hospital, Guangzhou Command of Chinese PLA between September 2006 and April 2008. MATERIALS: A total of 50 sets of dried Chinese adult human C1 and C2 specimens, without regard to gender and age, but no abnormality and breakage, were measured with an electronic digital caliper (precision 0.01 mm) and a goniometer(precision 0.5°) made in China. METHODS: One proper screw was drilled through the atlantoaxial joint respectively in the direction to middle part of laterosuperior angle in the posterior of C1 lateral mass, and the screw point should not break through the superior facet articularsurface of the C1. In the procedure, the screw drilling point was at the junction of the lateral border of C2 body to 4 mm above the inferior border of C2 anterior arch. border of transverse foramen of C2 body and the median line of C2 body, and the distance between the inserting point and the medial border of transverse foramen of C2 body. RESULTS: The data from all specimens were involved in the result analysis. In the sagittal plane, the minimum lateral angulation of the screw tract was (10.80±2.10)°(left) and (10.76±2.40)°(right) respectively, and the maximum lateral angulation was (25.13±3.12)°(left) and (25.12±2.86)°(right), respectively. In the coronal plane, the minimum posterior angulation was (8.85±2.12)° (left) and (9.28±2.65)° (right) respectively, and the maximum posterior angulation was (26.96±3.09)°(left) and (27.49±2.51)°(right), respectively. The left screw tract length was from (17.48±2.10) mm to (25.41±2.59) ram, and the right was from (17.49±2.23) mm to (25.58±2.42) mm. The left distance between the inserting point and the median line of C2 body was (9.84±0.69) mm, and the right was (9.81±0.66) mm. The left distance between the median line of C2 body and medial border of transverse foramen of C2 body was (14.12±1.28) mm, and the right was (14.60±1.36) mm. The left distance between the inserting point and medial border of transverse foramen of C2 body was (6.28±1.38) mm, and the right was (6.79±1.39) mm. CONCLUSION: It is optimal for the anterior C1-C2 transarticular screw fixation to place the antedor screw with a length of 17 to 25 mm in lateral angulation ranging from 10° to 25° and the posterior angulation ranging from 9° to 27°. During the procedure, the dissecting distance from the middle of C2 body to lateral should not exceed 14 mm.

12.
Chinese Journal of Orthopaedics ; (12)1999.
Article in Chinese | WPRIM | ID: wpr-543421

ABSTRACT

0.05). JOA scores of group A is higher than those of group B on 1, 2, 4 weeks postoperatively and the difference is of statistical significance (P

SELECTION OF CITATIONS
SEARCH DETAIL